The NEW Chapter 12, NCPI Engineering Manual
by NCPI - 10/31/2017

New Chapter on Operations and Maintenance of VCP lines 
Tips for Laying VCP
by NCPI - 09/23/2016

A brochure for tips on laying VCP with English and Spanish translations. 
Low Pressure Air Test Booklet
by NCPI - 08/01/2016

Procedures and Tables Based on ASTM C828: Standard Test Method for Low-Pressure Air Test of Vitrified Clay Pipe Lines 
2014 Updates to ASTM C12 Final Paper ASCE Pipelines 2015
by Jeff Boschert, P.E., MASCE and Amster Howard, MASCE - 01/07/2014

The ASTM standard C12 'Standard Practice for Installing Vitrified Clay Pipe Lines' gives recommended methods for installing vitrified clay pipe (VCP). C12 was significantly modified for the 2014 version (C12-14). 
Pilot Tube Microtunneling Chosen in Omaha Nebraska for 585’, Single Drive with Depths Reaching 50’ to Preserve Sensitive Garden Area
by David Gill, Chris Koenig, Chris Cain, Kenton Moore and Tim Papstein - 04/04/2014

Omaha, NE, stretching along the Missouri River for 7 miles, is currently under a consent order with the Nebraska Department of Environmental Quality to improve the water quality in the Missouri River. The estimated construction cost of the program, including sewer separation is $1.7 billion dollars. One projectdefined by the program was a sewer separation project, which took place in a very sensitive setting, Omaha's Lauritzen Gardens. 
Importance of Haunching
by Jeff Boschert, P.E., MASCE and Amster Howard, MASCE - 01/03/2014

Presented at ASCE Pipelines, 2014 - Testing on bedding practices that don’t include haunching reveal voids and call the assumption of uniform haunch support into question. 
CLSM as a Pipe Bedding
by Jeff Boschert, P.E. and John Butler - 01/08/2013

Presented at ASCE Pipelines, 2013 - CLSM as a structural bedding material for VCP. Optimal mixes, methodologies and resultant safety factors are discussed. 
Optimal CLSM Mix Design - As Developed by Means of Small Batch Testing
by NCPI - 01/06/2013

These tests were conducted to define the optimal mix for Controlled Low-Strength Material (CLSM) used in gravity sewer applications with vitrified clay pipe. Varying percentages of 3/8-inch coarse aggregate, accelerator and entrained air were tested. 
Guidelines for Controlled Low Strength Material (CLSM) Mix Design, Placement and Testing for Use as a Bedding Material for Vitrified Clay Pipe
by NCPI - 01/04/2013

Controlled Low Strength Material (CLSM) is used as a bedding material for Vitrified Clay Pipe to meet the requirements of ASTM C12 - Standard Practice for Installing Vitrified Clay Pipe, Section 6, Bedding and Encasement, and the National Clay Pipe Engineering Manual (2006), Chapter 4, Part II, Structural Design. 
Consideration for Flotation when CLSM is Used as a Bedding Material
by NCPI - 01/01/2013

No field installations using CLSM have resulted in flotation of clay pipe. CLSM is being successfully used as a bedding material for vitrified clay pipe. It simplifies the installation of pipe, reduces labor and inspection costs, allows for early backfill, is easy to place, and provides a 2.8 Load Factor. 
Consideration for the Use of Fly Ash when CLSM is Used as a Bedding Material for VCP
by NCPI - 01/01/2013

After research and testing, fly ash is not recommended as a component of the CLSM mix for pipe bedding. For more information on methods and results, see the full paper here. 
A Short Course in Pilot Tube Microtunneling
by David Gill - 01/01/2010

PTMT is generally used for new installation of small diameter gravity flow pipelines. These machines can operate out of a minimal diameter shaft and provide pinpoint accuracy through the use of a LED target viewed down the center of the pilot tubes with a theodolite and LCD monitor. The Pilot Tube Microtunneling (PTMT) method of pipeline installation can be used with pie outside diameters ranging from 4 to 48 inches. PTMT is a trenchless installation method for pipelines with grade and alignment precision to within 1/4 inch per 500 LF throughout the entire drive length. Due to this line and grade accuracy, this system can install product pipe by direct jacking without the use of casing. This method involves a three-step process starting with launch and reception pits strategically located to minimize surface disruption. 
A Guide to Analyzing CCTV Inspection
by NCPI - 01/01/2000

A Guide to Analyzing Televised Inspection 
The Evolution of Jointing Vitrified Clay Pipe
by Jack Evans and Marlene N. Spence - 08/27/1985

Advances made in the jointing of vitrified clay pipe during the last half century, illustrate the concern of the clay pipe industry to provide top quality jointing methods. Prior to this, the lack of standards for joint integrity meant testing for infiltration and Exfiltration was seldom implemented. Sewers were often designed simply to convey surface water, excessive groundwater and untreated sewage to area lakes, rivers, streams, estuaries and bays. Leakage was even designed into the system for cleaning purposes associated with high flow rates.